ERGOMERA-125.AV Ultrasonic Dual-Channel Heat Meter
The ERGOMERA-125.AV heat meter is designed for commercial and process metering of thermal energy, heat quantity, and the volumetric or mass flow rate of the heat-transfer medium in two pipelines, in accordance with the applicable heat energy metering regulations. It is recommended for use in both closed and open district heating systems, including boiler houses, combined heat and power plants, thermal power plants, industrial facilities, and heat distribution networks. The meter can be easily integrated into remote monitoring, dispatching, and SCADA systems.
A manager will contact you to clarify the price and confirm the order.
PURPOSE & SPECIFICATIONS
What It Measures
Heat-transfer fluid flow rate using the ultrasonic transit-time method
Temperature in the supply pipeline, return pipeline, and cold-water line
Pressure in the supply pipeline, return pipeline, and make-up water line, or liquid level
Thermal energy and thermal power
Temperature difference and differential pressure
Operating time, event logs, and process parameters
Key Advantages
✔ Ultrasonic measurement technology — no moving parts and reliable operation even with contaminated heat-transfer fluid
✔ High measurement accuracy — accuracy class 2 according to DSTU EN 1434, with sensors polled 16 times per second
✔ Dual-channel configuration — supports bidirectional and reverse flow measurement
✔ Installation under pressure — selected versions can be installed without shutting down the pipeline
✔ Minimal maintenance — sensors can be serviced without draining the heat-transfer fluid
✔ Near-real-time data transmission — ready for remote monitoring and automated data collection
✔ Extensive data archives — hourly, daily, and monthly records, as well as event and alarm logs
✔ Easy integration — open communication protocols and compatibility with virtually any SCADA system
Design and Available Versions
Threaded flow sensors — DN20 to DN40
Flanged flow sensors — DN20 to DN1200
Flangeless weld-in flow sensors
Type V2 — installation in an existing pipeline, DN250 to DN3200
Type V2-RShVS — pressurised installation with an airlock-type mounting assembly, DN250 to DN3200
Flow sensor materials: CW617N, AISI 304, AISI 316, cast iron, and Steel 20.
Ingress protection: calculator unit — IP54; ultrasonic flow sensors — IP68.
Technical Specifications
Parameter | Value |
|---|---|
Compliance | Technical Regulation No. 163 for Legally Regulated Measuring Instruments, DSTU EN 1434, DSTU 3339-96 |
Accuracy class according to DSTU EN 1434 | Class 2 |
Number of flow measurement channels | 2 |
Number of temperature measurement channels | 3 |
Number of pressure measurement channels | 3 |
Flow velocity range | 0.02–25 m/s |
Temperature measurement range | 0.1–150 °C; optional: −20 to +280 °C |
Operating pressure of the measured medium | 0.4–40 MPa; standard version: 1.6 MPa |
Maximum cable length | Up to 500 m |
Non-volatile data archive | Hourly — 1,480 records; daily — 160 records; monthly — 36 records |
Communication Interfaces and System Integration
Interface | Function |
|---|---|
LCD display | Displays current and archived measurement data |
RS232 | Primary built-in interface with DB9F connector |
RS485 | Modbus RTU, Ergo V1/V2; data rate up to 38,400 baud |
Ethernet | Modbus TCP, HTTP, and web interface |
4–20 mA | Analogue input or output |
Service keypad | Configuration of instrument parameters |
The following options are also supported:
Wireless M-Bus
LoRaWAN
NB-IoT
M-Bus
Pulse inputs and outputs
Data Archiving
The instrument’s non-volatile memory provides storage for the following data:
Archive | Capacity |
|---|---|
Hourly archive | Up to 1,480 records |
Daily archive | Up to 160 records |
Monthly archive | Up to 36 records |
Process archive | Up to 2,880 records |
Events and errors | Up to 2,000 records |
Operator interventions | Up to 500 records |
The archives contain measurement results for thermal energy, flow rate, temperature, and the volume or mass of the heat-transfer fluid. They also record operating time, downtime, and the duration of alarm or abnormal operating conditions.
Applications
Combined heat and power plants
Thermal power plants
Industrial and municipal boiler houses
Central and individual heating substations
Industrial facilities
District heating networks for monitoring heat-transfer fluid transportation and distribution losses
Configuration for a Specific Facility
The configuration of the ERGOMERA-125.AV is selected according to:
the heat supply system layout;
pipeline diameters;
flow measurement range;
heat-transfer fluid temperature and pressure;
the required number of measurement channels;
the selected data transmission method.
The system package may include:
one or two ultrasonic flow sensors;
temperature sensors with protective thermowells;
pressure sensors;
RS485 or Ethernet communication modules;
a GSM modem;
a control and mounting cabinet;
software for reading, processing, and analysing archived data.
ERGOMERA-125.AV — One Instrument for Metering, Monitoring, and Digitalisation of a Heat-Supply Facility
The appropriate version, nominal diameter, metering configuration, and data transmission equipment are selected according to the technical parameters and operating requirements of each facility.